Quantcast
Channel: VMware Communities : Discussion List - Site Recovery Manager
Viewing all articles
Browse latest Browse all 3691

Duplicate initiator error

$
0
0

I'm running into an issue with configuring the Array based Replication.

 

On Site A:

SRM 5.8 - Build 2336305

SRA 2.3.0 for Nimble storage

Physical:

BladeSystem c7000 Enclosure G2

ProLiant BL465c Gen8 -1

iSCSI:

iqn.1990-07.com.emulex:b4-b5-2f-58-57-11

iqn.1990-07.com.emulex:b4-b5-2f-58-57-11

 

ProLiant BL465c Gen8 - 2

iSCSI

iqn.1990-07.com.emulex:b4-b5-2f-58-e5-79

iqn.1990-07.com.emulex:b4-b5-2f-58-e5-79

 

ProLiant BL465c Gen8 - 3

 

On Site B:

SRM 5.8 - Build 2336305

SRA 2.3.0 for Nimble storage

Physical:

BladeSystem c7000 Enclosure G3

ProLiant BL465c Gen8 - 1

iSCSI

iqn.1990-07.com.emulex:38-63-bb-37-35-91

iqn.1990-07.com.emulex:38-63-bb-37-35-91

 

ProLiant BL465c Gen8 - 2

iSCSI

iqn.1990-07.com.emulex:38-63-bb-37-e6-b9

iqn.1990-07.com.emulex:38-63-bb-37-e6-b9

ProLiant BL465c Gen8 - 3


When trying to configure the Array replication Site B shows it's working fine. But on Site A I get a duplicate initiator error message.


Here is the following error on Site A BL465c - 1 error:

Discover Replicated Devices xx.domain.com Duplicate initiator 'iqn.1990-07.com.emulex:b4-b5-2f-58-57-12' found in SRA's 'discoverDevices' response.

 

2015-06-30T10:52:57.182-07:00 [02892 verbose 'PropertyProvider' opID=1fd9ba22] RecordOp ASSIGN: info.progress, dr.storage.ReplicatedArrayPair.discoverDevices16

2015-06-30T10:52:57.213-07:00 [02892 verbose 'Storage' opID=1fd9ba22] XML validation succeeded

2015-06-30T10:52:57.213-07:00 [02892 error 'Storage' opID=1fd9ba22] Duplicate initiator ID 'iqn.1990-07.com.emulex:b4-b5-2f-58-57-11' at (43:8):

--> <Initiator id="iqn.1990-07.com.emulex:b4-b5-2f-58-57-11" type="iSCSI"/>

2015-06-30T10:52:57.213-07:00 [02852 verbose 'PerformanceMonitor' opID=1fd9ba22] Performance monitor Token 0 of lock PersistableRWLock-3175 Locked took 7.488 seconds

2015-06-30T10:52:57.213-07:00 [02852 verbose 'PersistableRWLock' opID=1fd9ba22] Releasing Write lock 'PersistableRWLock-3175'

2015-06-30T10:52:57.213-07:00 [02852 verbose 'Storage' opID=1fd9ba22] Releasing read op lock on 'array-pair-3136'

2015-06-30T10:52:57.213-07:00 [02852 verbose 'PerformanceMonitor' opID=1fd9ba22] Performance monitor Token 0 of lock PersistableRWLock-3137 Locked took 7.504 seconds

2015-06-30T10:52:57.213-07:00 [02852 verbose 'PersistableRWLock' opID=1fd9ba22] Releasing Read lock 'PersistableRWLock-3137'

2015-06-30T10:52:57.213-07:00 [02852 info 'Storage' opID=1fd9ba22] Dr::Storage::VmomiLayer::DiscoverDevicesExecutor::DiscoveryComplete: discover devices completed

2015-06-30T10:52:57.213-07:00 [02852 error 'Storage' opID=1fd9ba22] Failed to discover devices at local site: (dr.storage.fault.DuplicateInitiator)

 

 

 

Any help or suggestions would be appreciated. Thanks in advance.